+86-18822802390

อะไร เกิดขึ้น ถึง ไฟ สายไฟ เมื่อ ทดสอบ ปากกา เป็น เสีย

Aug 16, 2023

เกิดอะไรขึ้น ถึง ไฟ สายไฟ เมื่อ ทดสอบ ปากกา เป็น เสีย

 

The internal part of the measuring pen is generally composed of high resistance resistors, neon tubes, and springs. The resistance value of this high resistance resistor is generally at the M Ω level, and it is in series with the neon tube to limit current and avoid large current flowing through the neon tube and the human body during testing. The possibility of damage to the resistor is very small, but if there is a fault such as poor contact between the resistor and the neon tube and spring, without knowing the fault, use the electric pen to measure whether the charged body has AC high voltage. At this time, the neon tube will not light up (or the brightness is weak), which may cause misjudgment and cause electric shock to the user. In addition, if the measuring pen accidentally enters water and is damp inside, using this pen to measure the AC220V voltage can also easily cause electric shock accidents. Therefore, before using the measuring pen, it is necessary to check its condition and confirm that there are no faults before using it.


% 0a เมื่อ ใช้ a ดิจิตอล มัลติมิเตอร์ แทน ของ a วัด ปากกา ถึง กําหนด ศูนย์ และ สด สายไฟ% 2c ช่วง สวิตช์ สามารถ สามารถ ตั้ง AC 2% 7b% 7b1% 7d% 7d% 7d0V แรงดันไฟฟ้า ช่วง สีดํา โพรบ ควร ติดต่อ พื้นดิน หรือ ผนัง% 2c และ สีแดง โพรบ ควร ติดต่อ สอง สายไฟ ตามลําดับ ถ้า red probe contacts zero wire% 2c the voltage displayed on the multimeter is very small % 2c close to 0V If the red probe contacts the live wire, the voltage displayed on the multimeter is generally tens of volts or more. Using this method to measure AC high voltage, unlike measuring an electric pen, there will be current flowing through the human body, which is safer.


① It's very อันตราย!


② However, the danger does not occur when measuring the live wire with a stylus. The high resistance resistors used in measuring pens are solid core resistors, also known as volumetric resistors, which are divided into two categories: organic synthetic solid core resistors and inorganic synthetic solid core resistors. This type of resistor is made by mixing and pressing granular conductive materials, non-conductive powder materials used as fillers, and adhesives. Granular conductive materials are carbon black and graphite; Non conductive powder materials include mica powder, quartz powder, glass powder, titanium dioxide powder (titanium dioxide powder), etc; Some adhesives use organic adhesives, while others use inorganic adhesives. The two categories of organic solid core resistors and inorganic solid core resistors mentioned earlier are distinguished based on the type of adhesive. This type of resistor has strong overload resistance, high reliability, and is not easily damaged. If it is damaged, it will also be in an open circuit state, meaning that although the neon tube is not damaged but does not light up, the person holding the measuring pen to measure the fire wire will not be electrocuted.

 

% e2% 91% a2 อันตราย ของ ไฟฟ้า ช็อต เกิดขึ้น เมื่อ a คน อุบัติเหตุ สัมผัส สด ลวด และ ได้รับ an ไฟฟ้า ช็อต เมื่อ ตัวต้านทาน ของ วัด ปากกา เป็น เสียหาย และ ปลุก คือ สูญหาย เนื่องจาก เดิม สด ลวด ถูก ชาร์จ!


% 0aIf ความต้านทาน ของ การวัด ปากกา (ส่วนใหญ่ ของแข็ง การปราบปราม ความต้านทาน% 2c กับ a ความต้านทาน ค่า ของ หลาย M) คือ หัก% 2c มัน สามารถ สามารถ แบ่ง เป็น สอง สถานการณ์% 3a



% 0aThe second is a ลัดวงจร (นี้ สถานการณ์ คือ หายาก)% 2c และ นีออน หลอด ของ วัด ปากกา แตก ลง เนื่องจาก ถึง ชั่วขณะ สูง แรงดันไฟฟ้า ( ปกติ ทํางาน แรงดันไฟฟ้า ของ นีออน ฟอง เป็น 70V) ที่ นี้ เวลา 2c ne ne tube เล่น a ความปลอดภัย บทบาท และ จะ ไม่ สาเหตุ อันตราย ถึง คน

 

digital voltage tester pen

ส่งคำถาม